High temperature and high pressure laboratory reactor supplier

ネゴシエーション可能更新03/06
モデル
メーカーの性質
生産者
製品カテゴリー
原産地

概要

The ethylene polymerization evaluation device is mainly used to evaluate and study the process, explore process parameters, obtain product distribution, product properties and other data through sampling analysis, evaluation and data processing, and provide design basis data for pilot and industrial process design.

製品詳細

Ethylene polymerization evaluation deviceThe design volume of the reaction vessel is 3L, and it is heated by a high and low temperature circulating oil bath machine. The main material of the equipment is 316L, and the stirring speed of the reaction vessel is 150-750rpm. A self-priming stirring blade is used to allow the gas above the liquid level in the reaction vessel to be sucked back below the liquid level, increasing the contact between gas and liquid and improving the reaction efficiency. The design pressure of the reaction vessel is 10MPa, the operating pressure is 6MPa, the design temperature is 200 ℃, and the operating temperature is 90 ℃. The device is designed with two flow meters for inlet: ethylene and carbon monoxide, both with a range of 1000sccm. The flow meter inlet design can increase the pressure of the reaction vessel from atmospheric pressure to reaction pressure, and can display instantaneous flow rate and cumulative flow rate. The device is designed with a vacuum pump interface, and the system can be evacuated before the experiment to reduce the water and oxygen content of the system. The device is equipped with a feeding tank, which can be removed and added to the glove box before being installed on the reaction vessel. During installation, nitrogen can blow the pipeline between the feeding tank and the reaction vessel.

Ethylene polymerization evaluation deviceIt is mainly used to evaluate and study the process, explore process parameters, obtain product distribution, product properties and other data through sampling analysis, evaluation and data processing, and provide design basis data for pilot and industrial process design.


parameter

Design pressure:

10MPa

Reaction pressure:

6MPa

Design temperature:

200℃

Reaction temperature:

90℃

Range of propylene mass flowmeter

2SLM and 5SLM each have a valley (used in the gas phase at room temperature, with a pressure difference of 0.3~0.5MPa before and after the mass flowmeter)

material

316L

total volume

3L